SKU: AFG-VR-36

AffiVET® Canine Lyme Antibody, Anaplasma ANA Antibody, Ehrlichia EHR Antibody, Heartworm CHW Antigen Rapid Test Kit

Vendor AffiGEN
Regular price $127.00 USD
Sale price $127.00 USD Regular price
Sale Sold out
Unit price
/per 
Shipping calculated at checkout.
Size:
This is a pre order item. We will ship it when it comes in stock.

AffiVET® Canine Lyme Antibody, Anaplasma ANA Antibody, Ehrlichia EHR Antibody, Heartworm CHW Antigen Rapid Test Kit

 

Cat Number: AFG-VR-36/AFG-VR-37
Size: 10/5 Tests
Species: Canine
Sample: Whole blood, plasma or serum


Test Principal:

The AffiVET® Canine Lyme Antibody, Anaplasma ANA Antibody, Ehrlichia EHR Antibody, Heartworm CHW Antigen Rapid Test Kit employs a chromatographic immunoassay technique to qualitatively detect antigens and antibodies associated with Dirofilaria immitis, Ehrlichia canis, Borrelia burgdorferi, and Anaplasma phagocytophilum/Anaplasma platys in canine serum, plasma, or whole blood.

This kit consists of a device featuring two lines: the test ("T") line and the control ("C") line. Initially, these lines are not visible. The appearance of the control line serves as a reference, indicating proper test performance. It should always appear after testing. If the sample contains the target antigens or antibodies, a purple test line will also appear in the result window.

The assay employs highly selective recombinant antigens or antibodies as capture or detector molecules. These molecules specifically target Dirofilaria immitis antigen (HW Ag), Ehrlichia canis antibody (E.canis Ab), Borrelia burgdorferi antibody (Lyme Ab), and Anaplasma phagocytophilum/Anaplasma platys antibody (Anaplasma Ab) in canine samples, ensuring high accuracy in detection.

Material Required:

(10/5) Rapid CaniV-4 Test Device
(10/5) Assay Diluent Tube
(10/5) Anticoagulant tube
(10/5) Disposable Capillary Tube (20µL)
(01) Instruction of Use
(01) Timer (Not Provided)
(01) Micropipette (Not Provided)

Storage & Stability:

  • Store the test kit at 2~30°C. DO NOT FREEZE.
  • Do not store the test kit in the direct sunlight.
  • The test kit is stable within the expiration date that marked on the package label.

Sample collection & Preparation:

1) This test requires whole blood, serum, or plasma.
  • Whole blood:

Collect whole blood into the provided anticoagulant tube (maximum volume 1.5 ml). If anticoagulated whole blood is not immediately tested, it should be refrigerated at 2~8°C and used within 24 hours.

  • Serum:

Collect whole blood into a collection tube (NOT containing anticoagulants such as heparin, EDTA, and sodium citrate), let it settle for 30 minutes for blood coagulation, and then centrifuge to obtain the supernatant.
  • Plasma:

Collect whole blood into a collection tube (containing anticoagulants such as heparin, EDTA, and sodium citrate) and then centrifuge to obtain plasma.

2) Serum samples should be stored at 2~8°C. For longer storage, freeze the samples at -20°C or below. Avoid repeated freezing and thawing.

3) Samples containing precipitate may yield inconsistent test results. They must be clarified before assaying.

4) Hemolyzed or contaminated samples may give erroneous results. Therefore, ensure sample purity by carefully assessing sample integrity. If hemolysis or contamination is detected, take corrective measures such as recollection or sample purification to avoid erroneous results.

Test Procedure:

  1. Ensure that all reagents and samples are equilibrated to room temperature (15~30°C) prior to initiating the assay.
  2. Take out the test device from the foil pouch and position it on a flat, dry surface.
  3. Using either a disposable capillary tube, add 20 μl of whole blood into each sample hole. Alternatively, use a micropipette to add 10 μl of serum/plasma into each sample hole.
  4. Dispense 2 drops of assay diluent into every sample hole.
  5. Begin the timer. The sample will migrate across the result window. If no result appears after 1 minute, add an extra drop of assay diluent to the sample hole.
  6. Read and interpret the test results precisely at the 15-minute mark. Do not analyze the results after this designated time.

Result Interpretation:

HW Ag/E.canis Ab/Lyme Ab/Anaplasma Ab Negative Result:

Presence of C-Line
Absence of T-Line

HW Ag/E.canis Ab/Lyme Ab/Anaplasma Ab Positive Result:

Presence of C-Line

Presence of T-Line

Notes:
Test strip of Anaplasma Ab can't differentiate between A.phagocytophilum
and A.platys: a positive result indicates presence of antibodies to A.
phagocytophilum and/or A. platys.
HW Ag/E.canis Ab/Lyme Ab/Anaplasma Ab Invalid Result:

Absence of C-Line
Presence of T-Line

Or

Absence of C-Line
Absence of T-Line

This means that the procedure was not applied correctly or that the test is invalid.

Test Limitations : 

  1. While the AffiVET® Canine Lyme Antibody, Anaplasma ANA Antibody, Ehrlichia EHR Antibody, Heartworm CHW Antigen Rapid Test Kit is highly accurate in detecting Dirofilaria immitis antigen, Ehrlichia canis antibody, Borrelia burgdorferi antibody, and Anaplasma phagocytophilum/Anaplasma platys antibody, occasional false results may occur. In cases of questionable results, additional clinical and/or laboratory tests may be necessary. It is important to note that a definitive clinical diagnosis should not rely solely on the outcome of a single test but should be determined by the veterinarian after evaluating all clinical and laboratory findings.

  2. The reading window may exhibit a light pink background coloration; however, this will not impact the accuracy of the results.

  3. AffiGEN and its distributors cannot be held liable for the repercussions of misuse or misinterpretation of the test results.