Load image into Gallery viewer, AffiVET® Bovine & Goat Tuberculosis (TB) Antibody Rapid Test
Load image into Gallery viewer, AffiVET® Bovine & Goat Tuberculosis (TB) Antibody Rapid Test
Load image into Gallery viewer, AffiVET® Bovine & Goat Tuberculosis (TB) Antibody Rapid Test
Load image into Gallery viewer, AffiVET® Bovine & Goat Tuberculosis (TB) Antibody Rapid Test
Load image into Gallery viewer, AffiVET® Bovine & Goat Tuberculosis (TB) Antibody Rapid Test

SKU: AFG-VGS-17

AffiVET® Bovine & Goat Tuberculosis (TB) Antibody Rapid Test

Vendor AffiGEN
Regular price €250,00 EUR
Sale price €250,00 EUR Regular price
Sale Sold out
Unit price
/för 
Shipping calculated at checkout.
Size:
Method:
Specimen:
Pre Order text

AffiVET® Bovine & Goat Tuberculosis (MTB) Antibody Rapid Test

CAT#: AFG-VGS-17
Size: 25 Tests
Method: Rapid Test
Species: Bovine & Goat
Specimen: Serum & Whole Blood

 

Product Insert

Test Principal:

  • This test strip uses a rapid immuno-chromatography technique to qualitatively detect Tuberculosis Antibodies in serum and whole blood samples from bovines and goats.
  • During testing, the Tuberculosis Antibodies in the sample bind with the antigens coated with the colloidal gold, forming complexes that move towards the other edge of the strip.
  • Upon reaching the T-line, the specific antigen on the membrane captures these complexes, resulting in the appearance of a T-line.
  • The presence of a C-line indicates the validity of the test.
  • If the T-line appears, it signifies the presence of Tuberculosis Antibodies in the sample.

    Material Required:

    25X MTB Test card
    25X Sample Buffer
    25X Dropper
    01X Use Manual

    Storage & Expiry Date:

    1. Store the test kit at 2~30°C. DO NOT FREEZE.
    2. Do not store the test kit in the direct sunlight.
    3. The test kit is stable within the expiration date marked on the package label.

    Sample collection & Preparation:

    Whole blood:

    • Collect fresh anticoagulated whole blood and use on the same day.
    • Whole blood without adding anticoagulant should be used immediately after collection.

    Serum:

    • Collect 2 to 3 mL of blood using a clean, dry tube following standard procedures.
    • Allow the blood to last undisturbed for approximately 1 hour until it coagulates.
    • After coagulation, centrifuge the tube at 4000 revolutions per minute (r/min) for 10 minutes. Alternatively, you can let the blood sit for about 2 hours until it coagulates and naturally separates into serum and clot.
    • Carefully separate the clear and bright serum from any hemolysis or contamination.
    • The serum should be stored at a temperature between 2°C to 8°C for short-term storage and at -20°C for long-term storage.

    Test Procedure:

    • Use dropper to absorb the well-prepared sample.
    • Drop 1 drop of serum or 2 drops of whole blood into the sample buffer tube vertically and slowly mix it for ready use. (Note that this step is very important, never add too much sample) 
    • Take out the test card from the bag.
    • Use the dropper to absorb the sample.
    • Drop 2 to 3 drops into the well marked with “S”.
    • Read the results in 10 to 15 min at room temperature.
    • The result is invalid after 15 min.

    Result Interpretation:

    Negative Result:

    • Presence of C-Line
    • Absence of T-Line

    This means there is no MTB antibodies in the sample or the level is lower than the detection threshold.

    Positive Result:

    • Presence of C-Line
    • Presence of Dark T-Line

    This confirms the presence of the MTB antibodies in the sample. It is a strong positive.

    • Presence of C-Line
    • Presence of Light T-Line

    This confirms the presence of the MTB antibodies in the sample. It is a weak positive.

    Invalid Result:

    • Absence of C-Line
    • Presence of T-Line

    or

    • Absence of C-Line
    • Absence of T-Line

    This means that the procedure was not applied correctly or that the test is invalid.

    Cautions:

    This kit is designed for detecting Tuberculosis antibodies in bovine  and goat sera. Please ensure you understand its intended use completely.

    • Read the manual carefully before use. The offered buffer can only be used for this test.
    • Avoid using serum from other animal species as a negative control. It is like using "no sample requirement" liquid.
    • Do not use product out of date or broken foil bag.
    • Return test card and sample buffer to room temperature after taking out from refrigerator, use the test card soon after open package to avoid dampness lead to invalidation.
    • Avoid using samples contaminated, with turbidity, severe hemolysis, and large amounts of blood lipids.
    • Do not touch the white membrane surface in the middle of test card, avoid sunlight and fan blowing directly.
    • The waste of test should be treated as pollution, handle it according to local regulations.